The solution to avoid zero anchor loads for piping

Alex Matveev is one of the authors of pipe stress analysis codes GOST 32388-2013 Process Piping, and GOST 55596-2013 District Heating Networks. He is also one of the developers of PASS/Start-Prof software, which is developed since 1965 and used in 95% of process, power, district heating, gas and oil transportation design companies in Russia and CIS countries; it is industry standard in that region.

Regular author into whatispiping.com, he gave details on a common design practice since 1950. The use of Factor k=0.8 is specified in codes SNiP 2.05.06-85 and SP 36.13330.2012. Also k=0.8 is offered in many Russian piping design and stress analysis handbooks.

Why Software may show Zero Anchor Loads?

While stress analysis and supporting considerations it is always a better engineering practice to provide line stops or axial stops or anchors at the neutral point of the straight portion of the piping. It is believed that at the neutral point, thermal movement is zero and frictional resistance equalizes from both sides of the piping system. In such a scenario, the frictional forces cancel out as forces are positive at one side and negative at the other. Also as there is no thermal movement, there will be zero axial loads due to temperature effect. So, the software will show zero anchor loads in such locations.

Example of Zero Anchor Loads

For example, In the following symmetric system with two U-shape loops as shown in Fig. 1, The leg length on both sides of the intermediate anchor is equal. Thus the intermediate anchor node 11 becomes a neutral point.

ZERO 1
Fig. 1: Symmetrical piping system with Intermediate Anchor

As can be seen in Fig. 2, The load along the pipe in an intermediate anchor (node 11) will be zero.

ZERO 2
Fig. 2: Zero Anchor Load for the System shown in Fig. 1

In reality, the piping heating up can be uneven, the friction forces can be different on the left and right part of piping, piping design can’t be ideal. Therefore, the real load on the anchor will not be zero.

How to Avoid Zero Anchor Loads?

To avoid such a situation the Anchor Factor “k” is used in piping stress engineering practice. The following method can be manually used in any pipe stress analysis software. In PASS/START-PROF piping stress analysis software this is a built-in function.

  • If loads from pipes to the left and right of the support  (N1 and N2) are in the same direction, they are combined as  N1+N2
  • If loads  N1 and N2 are in different directions, the lower values are multiplied by k and then combined as  N1+N2*k (|N2|<|N1|)
  • If the support is on an end node, factor  k is not used

Factor k applied only for loads in the horizontal plane: axial force, lateral force, horizontal moment.

The common value, that is recommended by some piping stress analysis codes is k=0.8. If we use 0.8 value the result will be as shown in Fig. 3. and Fig. 4.

ZERO 3
Fig. 3: Actual Anchor Load in Axial Direction
ZERO 4
Fig. 4: Intermediate Anchor with Actual Anchor Load in Start-Prof

The following training video shows how to create this model. It takes less than 10 minutes

For more details, contact us.